Model
SL-V08H
Beam axis spacing/Lens diameter
20 mm/ø5 mm
Detection capability
ø0.98" ø25 mm
Effective aperture angle
Max. ±2.5° (When operating distance is 3 m 98.23' or more)
Working distance
0.1 m to 9.0 m 0.30' to 29.53' (detection height of 1260 mm 49.61" or l ess)
0.1 m to 7.0 m 0.30' to 22.97' (detection height of 1400 mm 55.12" or more)
Response time (ms)
ON→OFF
7*1
OFF→ON
47*1
Light source
Infrared LED (850 nm)
Operation mode
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)
OSSD output
Output
2 outputs each for PNP and NPN. Can be changed by using the connector cable.
Max. l oad current
500 mA*2
Residual vol tage (during ON)
Max. 2.5 V (with a cable length of 7 m 22.97')
Leakage current
Max. 100 μA*3
Max. capacitive load
2.2 μF (with a load resistance of 100 Ω)
Load wiring resistance
Max. 2.5 Ω*4
Non safety-rel ated output
AUX
Output with automatic PNP/NPN switching function, 50 mA max.
Interlock-reset-ready output
Alarm output
Clear/blocked output
State information output 1, 2
Muting lamp output
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5can be connected
Input
EDM input
Short-circuit current 10 mA
Wait input
Short-circuit current 2.5 mA
Reset input
Muting input 1, 2
Override input
Protection circuit
Reverse current protection, short-circuit protection for each output, surge protection for each output
Approved standards
EMC
EMS
IEC61496-1, EN61496-1, UL61496-1
EMC
EN55011 Class A, FCC Part15B Class A
Safety
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1 (Category 4, PLe)
UL508
UL1998
Rating
Power voltage
24 VDC +10%, -20% (Ripple P-P 10% or less)
Current consumption (mA)
When the center indicator is ON
Transmitter
56*6
Receiver
70*6
When the center indicator is OFF
Transmitter
52*6
Receiver
65*6
Environmental resistance
Enclosure rating
IP65 (IEC60529)
Overvoltage category
II
Ambient temperature
-10 to 55°C (14 to 131°F), No condensation
Ambient temperature for storage
-13 to +140°F -25 to +60℃ (No freezing)
Relative humidity
15 to 85% RH (No condensation)
Storage relative humidity
15 to 95% RH
Operating ambientluminance
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.
Vibration
10 to 55 Hz, 0.03” 0.7 mm compound amplitude, 20 sweeps each in the X, Y and Z directions
Shock resistance
100 m/s2 (Approx. 10 G), 16 ms pulse in X, Y, Z directions, 1000 times each axis
Material
Main unit case
Aluminum
Upper case/lower case
Zinc die-cast
Front cover
Polycarbonate, SUS304
Weight
Transmitter
150 g
Receiver
155 g