OMRON MY4N-GS 24VAC ราคา 135 บาท
Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays
Operating Coil
Item
Rated current
(mA)
Coil
resistance
(Ω)
Coil inductance
(H)
Must-
operate
voltage
Must-
release
voltage
Max.
voltage
Power
consumption
(VA, W)
Rated voltage
50 Hz
60 Hz
Armature
OFF
Armature
ON
Percentage of rated voltage
AC
24
53.8
46
180
0.69
1.3
80% max.*1
30% min.*2
110%
Approx. 1.1
(at 60 Hz)
100/110
11.7/12.9
10.0/11.0
3750
14.54
24.6
Approx. 0.9 to
1.1 (at 60 Hz)
200/220
6.2/6.8
5.3/5.8
12950
54.75
94.07
220/240
5.2/6.2
4.3/5.0
15920
83.5
136.4
DC
24
36.3 (37.7)
662 (636)
3.2
5.72
10% min.*2
Approx. 0.9
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for the
AC rated current and +15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The values in parentheses for the rated currents and coil voltages of DC coils are for models with LED operation
indicators.
5. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
The Relay will operate if 80% or higher of the rated voltage is applied. However, to achieve the specified characteristics,
apply the rated voltage to the coil.
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure
release, use a value that is lower than the specified value.
Contacts
2 poles
4 poles
Resistive load
Inductive load
(cos φ = 0.4, L/R = 7 ms)
Resistive load
Inductive load
(cos φ = 0.4, L/R = 7 ms)
Contact configuration
DPDT
4PDT
Contact structure
Single
Contact material
Ag
Rated load
5 A at 220 VAC
5 A at 24 VDC
2 A at 220 VAC
2 A at 24 VDC
3 A at 220 VAC
3 A at 24 VDC
0.8 A at 220 VAC
1.5 A at 24 VDC
Rated carry current
5 A
3 A
Maximum contact voltage
250 VAC, 125 VDC
250 VAC, 125 VDC
Maximum contact current
5 A
3 A
Maximum switching
capacity
1,100 VA
120 W
440 VA
48 W
660 VA
72 W
176 VA
36 W
Minimum load
(reference values)*
1 mA at 5 VDC
* These values are guides for the switchable limits for minute load levels, such as in electronic circuits. Actual characteristics may be different.
These values will depend on the switching frequency, atmosphere, and expected reliability level. Confirm applicability in the actual system under actual application conditions.