Product classification
Monostable relays
Built-in LED indicator and diode type
Coil ratings
24 VDC
Operating indicator
LED
Coil surge killer
Diode
Contact type
DPDT
Contact method
Single
Contact material
Ag alloy
Contact rated load
110 VAC 10 A (Resistive load)
110 VAC 7.5 A (Inductive load (cos φ= 0.4))
24 VDC 10 A (Resistive load)
24 VDC 5 A (Inductive load (L/R = 7 ms))
Maximum switching voltage
250 VAC
125 VDC
Maximum switching current
AC: 10 A
DC: 10 A
Failure rate
100 mA at 5 VDC (failure level: P Reference value) (Switching frequency of 120 operations per minute)
Ambient temperature (Operating)
-25 to 40 ℃ (with no icing or condensation)
Ambient_humidity (Operating)
5 to 85%RH (with no icing or condensation)
Contact resistance
50 mΩ max., Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
Release time (Reset time)
25 ms max. (The operate or release time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23 ℃)
Insulation resistance
Between coil and contacts: 100 MΩ min. (at 500 VDC)
Between contacts of different polarity: 100 MΩ min. (at 500 VDC)
Between contacts of same polarity: 100 MΩ min. (at 500 VDC)
Dielectric strength
Between coil and contacts: 2000 VAC (50/60 Hz 1 min)
Between contacts of different polarity: 2000 VAC (50/60 Hz 1 min)
Between contacts of same polarity: 1000 VAC (50/60 Hz 1 min)
Vibration resistance (Destruction)
10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Vibration resistance (Malfunction)
10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Shock resistance (Destruction)
1000 m/s**2
Shock resistance (Malfunction)
200 m/s**2
Endurance (Mechanical)
100 million operations min. (switching frequency 18,000 operations/h)
Endurance (Electrical)
500,000 operations min. (23 ℃, switching frequency 1,800 operations/h)
Protective structure
Closed type (cover)
Terminal structure
Plug-in terminal
Weight
Approx. 40 g